{"id":1940,"date":"2026-02-20T15:25:29","date_gmt":"2026-02-20T07:25:29","guid":{"rendered":"https:\/\/ctschina.com.hk\/?post_type=product&#038;p=1940"},"modified":"2026-03-17T15:58:57","modified_gmt":"2026-03-17T07:58:57","slug":"nikon-eclipse-ti2-series","status":"publish","type":"product","link":"https:\/\/ctschina.com.hk\/?product=nikon-eclipse-ti2-series","title":{"rendered":"Nikon Eclipse Ti2 Series"},"content":{"rendered":"<h2>Key Features of Nikon Eclipse Ti2 Series<\/h2>\n<hr \/>\n<ul>\n<li>\n<h3><strong>Groundbreaking 25 mm Field of View (FOV)<\/strong><\/h3>\n<ul>\n<li>Captures nearly double the area compared to conventional optics.<\/li>\n<li>Maximizes large\u2011format CMOS camera sensors for high\u2011throughput imaging.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\n<h3><strong>High\u2011Performance Illumination<\/strong><\/h3>\n<ul>\n<li>Bright, uniform LED illumination with fly\u2011eye lens design.<\/li>\n<li>Large\u2011diameter fluorescence filter cubes for high signal\u2011to\u2011noise imaging.<\/li>\n<li>Compact epi\u2011fluorescence illuminator (Nikon&#8217;s D-LEDI) optimized for wide FOV imaging.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\n<h3><strong>Advanced Optical Techniques<\/strong><\/h3>\n<ul>\n<li>Supports DIC (Differential Interference Contrast), NAMC (Advanced Modulation Contrast), apodized phase contrast, and external phase contrast systems.<\/li>\n<li>Lambda series objectives with Nano Crystal Coat for multi\u2011channel fluorescence and weak signal detection.<\/li>\n<li>Auto correction collar for precise compensation of sample thickness and refractive index variations.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\n<h3><strong>Perfect Focus System (PFS)<\/strong><\/h3>\n<ul>\n<li>Real\u2011time correction of focus drift caused by temperature changes or vibrations.<\/li>\n<li>Compatible with a wide range of wavelengths (UV to IR) and applications (multi\u2011photon, optical tweezers).<\/li>\n<li>Optional water immersion dispenser for stable long\u2011term imaging.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\n<h3><strong>Intelligent Workflow Guidance<\/strong><\/h3>\n<ul>\n<li>Built\u2011in sensors and internal camera provide interactive guidance for alignment and operation.<\/li>\n<li>Assist Guide function offers step\u2011by\u2011step instructions on tablets or PCs.<\/li>\n<li>Automatic recording of microscope status in metadata for reproducibility and quality control.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\n<h3><strong>Compatibility &amp; Expansion<\/strong><\/h3>\n<ul>\n<li>Works seamlessly with Nikon\u2019s NIS\u2011Elements software for acquisition and analysis.<\/li>\n<li>Supports confocal, super\u2011resolution, and high\u2011content imaging systems.<\/li>\n<li>Integrates with Nikon\u2019s large FOV cameras (Digital Sight 50M, Digital Sight 10) for both high throughput and high content approaches.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p><strong>Nikon ECLIPSE Ti2 Series<\/strong> inverted research microscopes deliver a groundbreaking 25mm field of view (FOV), maximizing large-format CMOS sensors for doubled data throughput in high-speed, high-content imaging without compromises. Featuring an ultra-stable, drift-free platform with fly-eye LED illumination for uniform brightness edge-to-edge, high-transmittance epi-fluorescence, and large-diameter optics supporting DIC, phase contrast, and super-resolution applications, models like Ti2-E offer motorized intelligence, Perfect Focus System (PFS), hardware triggering, and sensor-guided workflows for reproducible live-cell, confocal, and time-lapse experiments.<\/p>\n<p>Nikon ECLIPSE Ti2 Series: Flagship inverted microscopes with 25mm FOV, drift-free stability, motorized automation (Ti2-E), and compatibility for super-res, confocal, and high-speed live imaging.<\/p>\n<p><a class=\"button\" href=\"https:\/\/downloads.microscope.healthcare.nikon.com\/phase7\/literature\/Brochures\/Ti2_2CE-MPOH-3_12602T_24P.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Learn More<\/a><\/p>\n","protected":false},"featured_media":2716,"template":"","meta":[],"product_brand":[95],"product_cat":[81,88],"product_tag":[],"class_list":["post-1940","product","type-product","status-publish","has-post-thumbnail","product_brand-nikon","product_cat-microscope-research","product_cat-microscope-clinical","pa_applications-assisted-reproduction-technology-art","pa_applications-biophysics","pa_applications-cancer-therapeutics","pa_applications-cell-molecular-biology","pa_applications-developmental-biology","pa_applications-drug-discovery","pa_applications-neurobiology","pa_applications-optogenetics","pa_applications-pathology","pa_applications-regenerative-medicine","pa_applications-virology","pa_product-categories-inverted-microscope","pa_types-research","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=\/wp\/v2\/product\/1940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=\/wp\/v2\/media\/2716"}],"wp:attachment":[{"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1940"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=1940"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1940"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ctschina.com.hk\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}